System requirement instruction | GSS-30KW off-grid photovoltaic system | |||
Design Basis | the system DC voltage is set to 220VDC | |||
System Configuration and Offer | ||||
Item | Part | Specification | Quantity | Remarks |
1 | Solar panel | GSO-POLY-270W | 96PCS | connection method:12 strings x 8parallels |
2 | PV combiner box | GSB4A | 2SET | 4 inputs, 1 output |
3 | Bracket | C-shaped steel | 1SET | Hot-dip zinc |
4 | Inverter with Controller built in | GSA220-30KVA(24KW) | 1 set |
1,Built-in 50A MPPT controller. Support grid/Diesel Input. 3,Pure sine wave, power frequency output. |
5 | GEL Battery | GSO12V-250AH | 54 PCS | total discharge capacity: 40Kwh |
Battery box | 1PC | |||
6 | Connector |
MC4 |
8pairs | |
7 | PV cables (solar panel to PV combiner box) |
4mm2 |
200M | Free for this length. If the client wants longer cables, the price needs to be confirmed again. |
8 | BVR cables with lugs (battery to inverter) | 10mm2 | 60M | |
9 | BVR cables with lugs (battery to inverter) | 35mm2 | 8M | |
Instructions |
1. In rainy days, the battery can support 15000W load work 5hours. 2. The maximum power load should not exceed 20KW (including inductive load impact: such as refrigerators, air conditioners, washing machines, etc. with motor load). 3. The battery can be fully charged in 3-4hours under STC sunshine condition. |
Solar Panel
Data
TYPE | GSP60-260 | GSP60-265 | GSP60-270 | GSP60-275 | GSP60-280 |
Maximum Power(Pmax) | 260W | 265W | 270W | 275W | 280W |
maximum Power Voltage(Vmp) | 38.1 | 38.3 | 38.4 | 38.5 | 38.7 |
maximum Power Current(Imp) | 8.50 | 8.61 | 8.73 | 8.52 | 8.38 |
Open Circuit Voltage(Voc) | 38.1 | 38.3 | 38.4 | 38.5 | 38.7 |
Short Circuit Current(Isc) | 9.01 | 9.10 | 9.221 | 9.25 | 9.34 |
Module Effciency(%) | 15.90% | 16.21% | 16.51% | 16.82% | 17.12% |
Tolerance Wattage(%) |
0±5 | ||||
Temperature Coeffcient of Isc | 0.05%/C | ||||
Temperature Coeffcient of Voc | -0.32%/C | ||||
Temperature Coeffcient of Pmax | -0.41%/C | ||||
Standard Test Environment | Irradiance 1000w/m 2 , Ambient temperature 25 C, Spectrum AMI .5 | ||||
Warranty | 10 years warranty, 25 years service life. |
Mounting system
Specification
Installation site: Concrete foundation or screw foundation |
Material: aluminum support and stainless steel bolts |
Module orientation: landscape or portrait |
Suitable module width:790mm to 1100mm |
Tilt angle: 5°/15°25°/10°/20°/30°/35°40°/45° |
Warranty: 10 years warranty, 25 years service life. |
Inverter
Technical parameter\Mode |
GSA96 |
GSA220 |
Rated capacity |
6-8KVA |
6-30KVA |
Storage battery input |
||
Rated voltage(VDC) |
96.0 |
220.0 |
Low Voltage Protective Value(VDC) |
86.4 |
194.4 |
Low Voltage Recovery Value(VDC) |
104.0 |
234.4 |
Over Voltage Protective Value(VDC) |
124.0 |
279.0 |
Over Voltage Recovery Value(VDC) |
120.0 |
270.0 |
Solar Input |
||
Maximum Input Power(KWP) |
5.7 |
12.8/25.6 |
Maximum Charge Current(A) |
50 |
50/100 |
Start Voltage(VDC) | 140 | 270 |
MPPT Voltage Range (VDC) | 110-280 | 260-450 |
Maximum Open Circuit Voltage(VDC) | 300 | 480 |
Floating(VDC) | 108.0 | 243.0 |
Bulk Charge Voltage(VDC) | 113.6 | 255.6 |
AC bypass(Optional) | ||
Allowable Input Voltage Range(VDC) | 220 ±15%/110 ±15%(other input voltage can be customized) | |
Input Frequency (HZ) | 50/60 ±3% | |
AC Charger | Optional | |
AC Output | ||
Output Waveform | L+N Pure Sine Wave | |
Output Voltage | 220VAC ±1%;110VAC- ±1%(other output voltage can be customized) | |
Output Frequency (HZ) | 50/60 ±1% | |
Output Waveform distortion rate(THD) | ≤2%(Liner Load) | |
Convert Efficiency(80% Resistive load) | ≥85% | |
Current Peak Factor | 3:1 | |
Overload Ability | 105-110%;1600seconds;110-125%,60seconds; >125%.1second | |
Display Method | LCD+LED | |
Protection | Input reverse protection, Input low voltage protection, Input over voltage protection,output overload protection, Output sgort circuit protection (no recovery automatically need to restart machine),Machiner over heating protection. | |
Communication Function | RS485/GPRS(Optional) | |
Environment | ||
Protective Level | IP 20 | |
Applied Altitude(M) | ≤5000(Above 1000 meters, rated power derating 1% every 100meters) | |
Allowable relative humidity | <95%Non-condensation | |
Environment temperature(℃) | -10~+50 | |
Noise (1 meter) | ≤50dB | |
Size and Weight | ||
D*W*H(MM) | 600*305*800/750*450*1100 | |
Weight (KG) | 80-85 | 80-95/120-140 |
Battery
Rated Voltage | 12V |
Capacity(10hr,1.80V/cell.25℃ | 250Ah |
Weight | 75±0.5kg |
Interior Resistance(completely charge) | 5.1mΩ 25℃ |
Max. discharge current | 30I10 A(3min) |
Self-Discharge(25℃) | <3%/mouth |
Using Temperature | Discharge at -45~50 ℃ Charge at -20~45 ℃ Storage at -30~40 ℃ |
Recommended Using Temperature | 15℃~25℃ |
Design life | 13-15 years |
Max. Charge Current | ≤0.25C10 |